FRIGIDAIRE
سایت دیفراست www.defrost.irمرجع تعمیرکاران لوازم خانگی
Solution |
Description |
ErrorCode |
Is the incoming water fl ow normal? Yes, go to step (4). No, go to step (2). Are the incoming water faucets turned on? No, turn water faucets on. Yes, go to step (3). Is the incoming water pressure above (30) psi? No, have customer correct pressure problem. Yes, check for kinked or blocked incoming water hoses, clean incoming water screens. If problem still remains, replace the water inlet valve assembly. Does the fi ll water continue to enter the washer? Yes, go to step (5) no, go to step (6). Remove power from washer. Did the water fi ll stop? Yes, go to step (6). No, replace the inlet valve assembly. For Better models, check the electronic pressure sensor. For Good models, check the pressure switch. Pressure sensor checks good. Go to step (7). Pressure sensor checks incorrect. Replace pressure sensor. Replace the Main Control Board. |
Fill time too longص |
E10/E11 |
Is the washer leaking water? Yes. Correct water leak. No. Go to step (2). Is there a leak in the air bell system? Yes. Correct the leak problem. No. Go to step (3). For Better models, check the electronic pressure sensor. For Good models, check the pressure switch. Defective. Replace pressure sensor(switch). Good. Go to step (4) Replace the Main Control Board |
Water leak in tub or air leak in air bell |
E13 |
Is the dispenser drawer closed? No, close the drawer. Yes, go to step (2). Remove the drawer and check the magnet. Magnet missing or defective, replace the magnet. Magnet good. Go to step (3). Open the console and check the reed switch. Defective, replace the reed switch. Good, replace the Main Control Board. |
Reed Switch |
E14 |
Check the drain hose for restrictions. Restriction, correct problem. No restriction, go to step (2). Start the washer and check for 120VAC at the drain pump. Zero, replace the Main Control Board. 120VAC, remove the pump and check it for blockage. If blocked, remove the restriction, if not, replace the pump. |
Water not pumping out fast enough |
E20/E21/E22 |
Replace Main Control Board or repair wiring | Drain pump relay on board failed or wire off pump |
E23 |
Replace Main Control Board or repair wiring | Drain pump relay on board failed or wire off pump |
E24 |
Check wiring between Main Control Board and pump. If correct, go to step (2). Check wiring between Main Control Board and recirculation board. If correct, go to step (3). Check pump for open coil (resistance check). If correct, replace Main Control Board. |
Recirculation pump relay sense |
E25 |
Check wiring between Main Control Board and pump. If correct, go to step (2) Check wiring between Main Control Board and recirculation board. If correct, go to step (3). Check pump for open coil (resistance check). If correct, replace Main Control Board. |
Recirculation pump relay |
E26 |
سلام
با تشکر از شما ارورهائی که در بالا ذکر شده مربوط به یخچالهای وایت وستیگهاوس-گیسبون و کلویناتور تمامی ارور مربوط به سیبتم ابرسانی می باشد و در خصوص سیتم تبریدی مطلبی ندارد اگر مورد مشخص در دسترستان می باشدباشد لطف فرمائید برای استفاده تعمیرکاران قرار دهید .
با تشکر تمیزکار
درود
لطفا مدل کامل دستگاه مورد نظر را بفرستید .